REPORT OF TEST

Report #:

022884

Date:

10/07/93

Client:

Scahner's Waste Water Products, Inc.

Attn:

John Scahner

SAMPLE IDENTIFICATION:
One (1) liquid sample submitted and identified by Client as follows:

Polygone™ (already mixed)

TEST PERFORMED AND RESULTS:
Resistance to Chemical Damage
Visual

Samples of dewatering belt were immersed in Polygone and distilled water for 72 hours. After air-drying, both samples were examined at magnifications ranging from 10X-200X and compared to an unexposed belt sample. No evidence of chemical damage is observed. Exposed samples and photomicrographs at 100X are enclosed for evaluation by Client.